Air Conditioning Designer

۳۳ مطلب با کلمه‌ی کلیدی «Chiller» ثبت شده است

ChillerPlant3DModeling|2023|Shiraz

ChillerPlant3DModeling|2023|Shiraz

Utilizing hashtag#bim Methodology, we meticulously designed a 60-ton Aircooled hashtag#chiller Plant to meet stringent air conditioning requirements within confined spaces and restrictive walls, as per our discerning client's specifications. Leveraging hashtag#plant3d software, our team adeptly configured the Chiller Plant layout, strategically placing the Chiller and dual pumps within the limited area. Despite these physical constraints, our innovative approach prevailed, resulting in an intelligently integrated system that not only met but surpassed performance expectations. Additionally, through hashtag#bim , we seamlessly generated an accurate hashtag#bill_of_materials (hashtag#BOM), highlighting components and quantities, ensuring precise implementation of this hashtag#high_efficiency hashtag#air_conditioning solution tailored precisely to our client's needs.

 

 

ادامه مطلب...
۰ نظر موافقین ۰ مخالفین ۰
چالش تغییرات دبی در سیستم تهویه مطبوع

چالش تغییرات دبی در سیستم تهویه مطبوع

امروزه با توجه به گرم شدن بیش از حد هوا در تمامی نقاط زمین ایجاد شرایط آسایشی دمایی یکی از نکات و شرایط مهم در تمامی ساختمان ها می باشد. از زاویه نگاهی دیگر همچنان که ایجاد  آسایش دمایی اهمیت حیاتی پیدا کرده است , لزوم انتخاب سیستم های بهینه , پیشرفته و همچنین تطابق آنها با نیاز واقعی پروژه ها بسیار مهم می باشد. دلیل آن نیز هزینه های اولیه بسیار بالا و همچنین هزینه های انرژی بسیار گران برای بهره برداران می باشد.


در همین رابطه میتوان پیشنهاد اکید اشری (Ashrae) مبنی بر انتخاب سیستم های تهویه مطبوع بر اساس ضریب اطمینان کمتر "1" بسیار قابل توجه می باشد. در حقیقت انجمن گرمایش، سرمایش و تهویه مطبوع آمریکا"Ashrae" بر این عقیده است که محاسبه نیاز خنک کاری یک پروژه بر اساس گرم ترین ساعت و روز یک سال می باشد و با توجه به اینکه این زمان حدود چند درصد کل سال می باشد , در صورت صرف نظر از آن می توان از یک سیستم خنک کننده با ظرفیت  پایین تر استفاده نمود که این یعنی کاهش ظرفیت و سایز تمامی تجهیزات شامل چیلرها , پمپ ها , لوله کشی . در حقیقت ارزش کاهش مصرف انرژی بیشتر از  کاهش سطح آسایشی برای ساعاتی در چند روز محدود می باشد.


در یک جمله انتخاب تجهیزات بر اساس ضریب های اطمینان بالای "1" و انتخاب سیستم هایی بیشتر از نیاز بطور کلی منسوخ شده است.
 

ادامه مطلب...
۰ نظر موافقین ۰ مخالفین ۰
BIM Modeling|2023|Ramak Dairyl |Shiraz

BIM Modeling|2023|Ramak Dairyl |Shiraz

 

 

 

 

 

 

 

 

        

۰ نظر موافقین ۰ مخالفین ۰
Central MechRoom BIM|2022|Azin Mall Project|Shiraz

Central MechRoom BIM|2022|Azin Mall Project|Shiraz

Project type : Comercial

Application : Mall

Year : June-2022

Location : Shiraz-IRI

 

Additional Information and Details: I Designed that project with Revit and HVAC Solution, but we needed BOM (Bill Of Material) and an isometric plan. Thats Why I redesigned it with Plant3d. Plant 3d gives us a lot of opportunity such as BOM list, Isometric plan, 3d plan and it was very fast and easy to work.



 

 

ادامه مطلب...
۰ نظر موافقین ۰ مخالفین ۰
Central MechRoom BIM|2022|Mall Project|Shiraz

Central MechRoom BIM|2022|Mall Project|Shiraz

Project type : Mall

Application : Central Mech Room Designe by BIM method and Revit MEP.

Year : 2022

Location : Shiraz-IRAN

 

ادامه مطلب...
۰ نظر موافقین ۰ مخالفین ۰
BIM | Emam Ali Day Clinic | Fasa 2021

BIM | Emam Ali Day Clinic | Fasa 2021

Project type : Day Clinic

Application : BIM - 3D - Piping Simulation - Mech Room - Full Air Conditioning

Year : 2020-2021

Location : IRI - Fasa

 

Additional Information and Details: I designed and simulation that project 2 years ago. Now, thats construction process restart again. It has some wonderful and special issues like, surgery room and a small mech room that was located on the roof. Another thing that I had to take in my consideration is, everything that was designed in that project needed specific details.

ادامه مطلب...
۰ نظر موافقین ۰ مخالفین ۰

Iran IHE&R 1400 | Tehran International Exhibition Center

۰ نظر موافقین ۰ مخالفین ۰
تاثیر نما دوپوسته در تهویه مطبوع

تاثیر نما دوپوسته در تهویه مطبوع

مطابق اعلام شورای ساختمانهای بلند و زیستگاه شهری که یک سازمان بین المللی و واقع در کشور آمریکا و کار آن تعیین و انتخاب ساختمان های بلند می باشد , حدود 33 درصد از انرژی مصرف شده در یک ساختمان بلند مرتبه صرف سیستم های تهویه مطبوع می گردد. از این رو تلاش تمامی مهندسان و طراحان پروژه های ساختمانی در جهت کاهش هرچه بیشتر این میزان انرژی حتی در حدود چند درصد بوده است.

 

ادامه مطلب...
۰ نظر موافقین ۰ مخالفین ۰
MechRoom | Neyriz Central Hospital |Neyriz 2021

MechRoom | Neyriz Central Hospital |Neyriz 2021

 

۰ نظر موافقین ۰ مخالفین ۰
Chiler Piping | Shiraz municipality |Shiraz 2021

Chiler Piping | Shiraz municipality |Shiraz 2021

Project type : Office

Application : Chiller Piping Design - Observating - 3d - BIM

Year : 2021

Location : IRI - Shiraz

Additional Information and Details:  That Project was related to Shiraz central municipality building. It was very important and critical. Everything and every detail were very special and I had to check it. So BIM method was very helpful and useful. I had to design piping and estimate install conditions for the 3700kw air-cooled chiller.

ادامه مطلب...
۰ نظر موافقین ۰ مخالفین ۰